Voltage Current Monitor-EN Specifications

OUTPUT ¹:
Continuous Monitoring:
Local: 3 ½ digit liquid crystal display indicating Peak Current, Average Current, Peak Shaft Voltage * or Power/Alarm Check, selectable with rotary switch
Remote: 4 to 20 mA signal representative of Peak Ground (Earth) Current
4 to 20 mA signal representative of Average Ground (Earth) Current
4 to 20 mA signal representative of Peak Shaft Voltage *
Alarms ²:
Local: LED for minimum and maximum brush current and maximum shaft voltage *
Remote: Open contact on minimum and maximum current, maximum shaft voltage and loss of power supply to the unit * (User selectable latching is optionally available in Non-Explosion-Proof Enclosures Only)
INPUT: Ground (Earth) Current Lead (from shunt in ground (earth) circuit)
Voltage Lead (from shaft-monitoring, voltage sensing brush)
POWER REQUIREMENTS: 115 - 240 Vac, 50/60 Hz to power supply module supplied by MPS, to be mounted by user. Contact MPS for optional configurations.
HARDWARE REQUIREMENTS: 100 mV shunt for 1, 2, 5, 10, 20, 50, 100, or 200 A (MPS supplied).
TEMPERATURE:
Operating: -10°C to 50°C (14°F to 122°F)
Storage: -23°C to 60°C (-10°F to 140°F)
Relative Humidity: 0% to 95%, non-condensing
BASIC ENCLOSURE DIMENSIONS - Not to be used for construction purposes:

Non-Explosion Proof:

Non-Explosion Proof:

Explosion Proof:

Single

Dual

All Models

Height:

5.00 in. (127 mm)

4.65 in. (118 mm)

7.60 in. (193 mm)

Length:

7.31 in. (185.7 mm)

11.81 in. (300 mm)

7.60 in. (193 mm)

Width:

7.31 in. (185.7 mm)

10.25 in. (260 mm)

7.80 in. (198 mm)

Weight:

3 lbs. (1.36 kg)

7.5 lbs. (3.4 kg)

15 lbs. (6.8 kg)

OPTIONS: Additional visual or audible alarms
Custon Enclosures with multiple VCM-E's
Signal consolidation
Vibration mounting plates
Hazardous Atmosphere or Flame Proof Certifications available
¹ Accuracy: ±1% of maximum rating.
² Minimum Current is 3% (adjustable) of maximum rating, indicating possible loss of brush contact with shaft. Maximum Current is 100% of shunt rating.
Maximum voltage is 0.1, 1 or 10 V (preset at factory, based on information provided by user).
* Voltage-sensing brush required [ie: One brush for voltage readings and one brush for grounding (earthing)].